High Performance Vacuum Pump
Models 15402 and 15602
Operating
M
anual
Model No. 15602
Seitenansicht 0
1 2 3 4 5 6 ... 11 12

Inhaltsverzeichnis

Seite 1 - Operating

High Performance Vacuum PumpModels 15402 and 15602Operating ManualModel No. 15602

Seite 2

10124567811Replacement PartsPart Item No. 15402 15602Intake Fitting 1 15364 555124Intake Caps (1/4", 3/8", and 1/2" are; 1 ea.)

Seite 3

Pump SpecicationsModel 15402 15602Free Air Displacement 4 CFM 6 CFM 93 l/m @ 50 Hz 142 l/m @ 50 Hz 113 l/m @ 60 Hz 170 l/m @ 60 HzStages 2 2Mo

Seite 4 - WARNING!

655 Eisenhower DriveOwatonna, MN 55060 USATechnical Services: 1-800-822-5561 Fax: 1-866-259-1241Customer Service: 1-800-533-6127 Fax: 1-800-283-866

Seite 6

3Robinair High Performance Vacuum Pumps Congratulations on purchasing one of Robinair’s top quality vacuum pumps. Your pump has been engineered speci

Seite 7

4WARNING!Wear safety goggles when working with refrigerants. Contact with refrigerants may cause eye injury.Incorrect use or electrical connections ma

Seite 8 - Troubleshooting Guide

5Before using your vacuum pump... Note on Motor Voltage Connections: In all cases, motors are designed for operating voltages, plus or minus 10% of

Seite 9 - Warranty Coverage

6To use the gas ballast feature... Moisture from the A/C-R system that is carried into the pump as a vapor tends to condense into a liquid and combin

Seite 10 - Replacement Parts

7To maintain the high vacuum pump... For maximum performance, Robinair recommends changing vacuum pump oil after each use. The condition and type of

Seite 11 - Pump Specications

8 b) Another method of dealing with heavily contaminated oil is to force the oil from the pump reservoir. To do this, allow the pump to run until i

Seite 12

9 3. Verify the pump oil is clean. A badly contaminated pump may require several oil ushes. See OIL CHANGE PROCEDURE. Note: Use only high vacuum pu